Oil boiler or furnace won't start: should I press the reset button?
Never press the oil burner reset button more than once. Repeated resets can flood the combustion chamber with oil and cause a puffback or fire.
Press the red reset button on the oil burner once, and only after checking that the tank has oil, the emergency switch is on, and the thermostat is calling for heat. If the burner does not start and stay running after that one press, stop and call a technician. Pressing reset repeatedly pumps unburned oil into the chamber, which can cause a puffback that spreads soot through the house.
Try this first
Check the oil tank
Read the gauge on top of the tank. If it is at or near empty, call for a delivery. A burner that ran dry usually needs to be bled before it will run, which a technician does.
Check the emergency switch
There is a red-plated switch at the top of the basement stairs or at the boiler room door. It is easy to flip by mistake when reaching for a light.
Check the thermostat
Set it to Heat and above room temperature, and replace batteries if the screen is blank.
Press reset once
The red button is on the burner control box. Press it once and release. If the burner lights and keeps running, watch it through one cycle.
If it locks out again, stop
Do not press reset again. Call for service and tell them it locked out after one reset.
Call a technician if
- The burner locks out after one reset.
- You ran out of oil (the line usually needs bleeding).
- You smell oil or exhaust, or see smoke or soot.
- The burner rumbles, puffs or shakes when it starts.
In Connecticut homes
Oil heat is still common in Connecticut, especially in older homes with boilers. Schedule a cleaning every year before the season: a clean nozzle, filter and combustion check prevent most no-heat calls and puffbacks.
Common questions
- Why does the reset button pop?
- The control trips when it does not see a flame within a few seconds. Causes include no oil, a clogged nozzle or filter, a dirty flame sensor, or an ignition problem.
- What is a puffback?
- A small explosion of oil vapor in the burner that blows soot out through the house. Repeated resets are a common cause.
- Can I bleed the oil line myself?
- It is possible but messy and easy to get wrong. Most homeowners call; it is a quick visit.