Short answer

A furnace that runs a few minutes, shuts off, and starts again is short cycling. The usual causes are a clogged filter or blocked vents making it overheat, a dirty flame sensor that cannot confirm the flame, a thermostat in a bad spot, or a furnace that is too big for the house. Change the filter and open the vents first. If it keeps happening, have the flame sensor and safety switches checked.

Try this first

  1. Replace the filter

    Overheating is the most common cause. A clean filter often fixes it the same day.

  2. Open supply and return vents

    Closed or blocked registers raise the temperature inside the furnace. Keep at least most of them open, and keep furniture off returns.

  3. Watch one full cycle

    If the burner lights, then goes out within about 10 seconds and retries, that points to the flame sensor. If it runs several minutes and the burner shuts off while the blower keeps going, that points to overheating.

  4. Check where the thermostat is

    A thermostat near a supply vent, a sunny window, or a kitchen satisfies too fast and shuts the furnace off early.

  5. Look for a blinking code

    Note the status light pattern; many boards log the last few faults.

Call a technician if

In Connecticut homes

Many Connecticut houses had furnaces sized generously decades ago, then got new windows and insulation. An oversized furnace short cycles by design. If yours is near the end of its life, that is worth knowing before you replace it.

Common questions

Is short cycling bad for the furnace?
Yes. Starts are the hardest part of the cycle on the igniter, blower motor and heat exchanger, and it wastes fuel.
What is a flame sensor?
A thin metal rod in the burner flame. If it is coated, the furnace cannot confirm the flame and shuts the gas off for safety. Cleaning it is a quick service call.
Can the thermostat cause short cycling?
Yes, through bad placement, a loose wire, or a setting that controls how often it cycles. Try moving the setpoint a few degrees and watch.